Shielded Data Cable Cat.7A S/FTP 23 AWG x 4P
a Cat.7A S/FTP network data cable, which consists of 4 twisted pairs of copper wires 23AWGx4P, aluminum polyester foil for each pair, and an overall tinned copper braid screen. This Cat.7A S/FTP 23 AWG x 4P Furukawa cable is used for patch panels in technical rooms and connectors in work areas, in Data Centers.
- Brand:Furukawa Electric
Code: Cat.7A-S/FTP-23-AWG-x4P


Shielded Data Cable Cat.7A S/FTP 23 AWG X 4P
a Cat.7A S/FTP network data cable, which consists of 4 twisted pairs of copper wires 23AWGx4P, aluminum polyester foil for each pair, and an overall tinned copper braid screen. This Cat.7A S/FTP 23 AWG x 4P Furukawa cable is used for patch panels in technical rooms and connectors in work areas, in Data Centers.
Constructive Characteristics | |
---|---|
Shielding | Twisted pair foiled with aluminum polyester tape and overall pairs with tinned copper braid screen |
Color | LSZH: Gray |
Additional colors on request | |
Nominal diameter | 7.9 mm |
Cable weight | 61 kg/km |
Flammability class | LSZH: Should comply with IEC 60332 Part 3-25: “Test for vertical flame spread of LSZH vertically mounted bunched wires or cables” |
Number of pairs | 4 pairs, 23 AWG |
Installation temperature |
From 0 °C to 50 °C |
Storage temperature |
-20 °C up to 75 °C |
Operation temperature |
-20 °C up to 60 °C |
Performance | |
Maximum unbalance resistance | 2 % |
Conductor maximum DC electric resistance at 20°C | 73.2 Ω/km |
Maximum mutual capacitance 1kHz | 56 pF/m |
Maximum unbalance capacitance pair x ground | 1.6 pF/m |
Characteristic impedance | 100 ± 15 % Ω |
Maximum propagation delay | 545 ns/100 m @ 10 MHz |
Maximum delay skew | 25 ns/100 m |
Electric voltage between conductors test | 2500 VDC/3 s |
Electric voltage between conductors and shielding test | 500 VDC/3 s |
NVP | 65% |
Insulation resistance | 5000 MΩ.km |
Package | |
Wood reel | |
Standard cable run | 305 m |